{"product_id":"extrascan-head","title":"ExtraScan Head","description":"\u003cp\u003e\u003cstrong\u003eExtraScan Head\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe ExtraScan Head is a fully digital scanning galvanometer built for high precision and low-drift requirements. It covers 10 \/ 14 \/ 20 \/ 30 mm aperture 2D galvanometers with an independently developed high-precision grating encoder and 23-bit position resolution, delivering excellent positioning and repeated-positioning accuracy. A flexible FPGA-based digital drive board can be matched to galvanometers with different loads, and the all-digital design minimises drift and maximises stability. Three series are available: ExtraScan I, ExtraScan II and ExtraScan IV.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e2D laser scan head with 10\/14\/20\/30mm aperture\u003c\/li\u003e\n\u003cli\u003eSelf-developed high-precision grating encoder. 23bit position resolution digital motor achieves excellent positioning accuracy and repeatability.\u003c\/li\u003e\n\u003cli\u003eSupports galvanometer position monitoring and position feedback to detect the status of the galvanometer in real time, ensuring safe and reliable operation of the galvanometer\u003c\/li\u003e\n\u003cli\u003eAll digital design ensures minimized drift and maximized stability.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications of ExtraScan Head\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct\u003c\/td\u003e\n\u003ctd\u003eExtraScan Head\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eFully digital 2-axis (2D) galvanometer scan head with FPGA drive board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAperture Range\u003c\/td\u003e\n\u003ctd\u003e10 \/ 14 \/ 20 \/ 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePosition Resolution\u003c\/td\u003e\n\u003ctd\u003e23 bit (grating encoder)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eWater cooled (5 l\/min at △p \u0026lt; 0.1 bar, p \u0026lt; 4 bar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Applications\u003c\/td\u003e\n\u003ctd\u003eHigh precision laser scanning and marking, where low drift and high repeatability are required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eExtraScan I\u003c\/th\u003e\n\u003cth\u003eExtraScan I 10\u003c\/th\u003e\n\u003cth\u003eExtraScan I 14\u003c\/th\u003e\n\u003cth\u003eExtraScan I 20\u003c\/th\u003e\n\u003cth\u003eExtraScan I 30\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Beam Aperture (mm)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBeam Displacement (mm)\u003c\/td\u003e\n\u003ctd\u003e12.54\u003c\/td\u003e\n\u003ctd\u003e16.42\u003c\/td\u003e\n\u003ctd\u003e25.25\u003c\/td\u003e\n\u003ctd\u003e35.53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcceleration Time (ms)\u003c\/td\u003e\n\u003ctd\u003e0.30\u003c\/td\u003e\n\u003ctd\u003e0.40\u003c\/td\u003e\n\u003ctd\u003e0.65\u003c\/td\u003e\n\u003ctd\u003e1.20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTracking Error (ms)\u003c\/td\u003e\n\u003ctd\u003e0.21\u003c\/td\u003e\n\u003ctd\u003e0.24\u003c\/td\u003e\n\u003ctd\u003e0.24\u003c\/td\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability (µrad)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOffset Drift (µrad\/K)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 15\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 15\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 15\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGain Drift (ppm\/K)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 8\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 8\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 8\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong-term Drift Over 8 Hours (mrad)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.08\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.08\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.08\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.08\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 % of Full Scale (ms)\u003c\/td\u003e\n\u003ctd\u003e0.45\u003c\/td\u003e\n\u003ctd\u003e0.60\u003c\/td\u003e\n\u003ctd\u003e0.85\u003c\/td\u003e\n\u003ctd\u003e1.30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 % of Full Scale (ms)\u003c\/td\u003e\n\u003ctd\u003e1.30\u003c\/td\u003e\n\u003ctd\u003e1.50\u003c\/td\u003e\n\u003ctd\u003e2.60\u003c\/td\u003e\n\u003ctd\u003e4.80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePositioning Speed (m\/s)\u003c\/td\u003e\n\u003ctd\u003e12.5\u003c\/td\u003e\n\u003ctd\u003e10.0\u003c\/td\u003e\n\u003ctd\u003e5.0\u003c\/td\u003e\n\u003ctd\u003e3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScan Angle (°)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGain Error (mrad)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u0026lt; 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero Offset (mrad)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u0026lt; 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±15 VDC, ≥ 3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e16bit: XY2-100   20bit: ST2-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Temperature (°C)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e25 ± 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Water Requirements\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e5 l\/min at △p \u0026lt; 0.1 bar, p \u0026lt; 4 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e1.9\u003c\/td\u003e\n\u003ctd\u003e2.3\u003c\/td\u003e\n\u003ctd\u003e5.0\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eExtraScan II\u003c\/th\u003e\n\u003cth\u003eExtraScan II 10\u003c\/th\u003e\n\u003cth\u003eExtraScan II 14\u003c\/th\u003e\n\u003cth\u003eExtraScan II 20\u003c\/th\u003e\n\u003cth\u003eExtraScan II 30\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Beam Aperture (mm)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBeam Displacement (mm)\u003c\/td\u003e\n\u003ctd\u003e12.54\u003c\/td\u003e\n\u003ctd\u003e16.42\u003c\/td\u003e\n\u003ctd\u003e25.25\u003c\/td\u003e\n\u003ctd\u003e35.53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcceleration Time (ms)\u003c\/td\u003e\n\u003ctd\u003e0.2\u003c\/td\u003e\n\u003ctd\u003e0.25\u003c\/td\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003ctd\u003e0.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTracking Error (ms)\u003c\/td\u003e\n\u003ctd\u003e0.21\u003c\/td\u003e\n\u003ctd\u003e0.24\u003c\/td\u003e\n\u003ctd\u003e0.24\u003c\/td\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability (µrad)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOffset Drift (µrad\/K)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 15\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 15\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 15\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGain Drift (ppm\/K)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 8\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 8\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 8\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong-term Drift Over 8 Hours (mrad)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.05\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.05\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.05\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 % of Full Scale (ms)\u003c\/td\u003e\n\u003ctd\u003e0.35\u003c\/td\u003e\n\u003ctd\u003e0.6\u003c\/td\u003e\n\u003ctd\u003e0.75\u003c\/td\u003e\n\u003ctd\u003e1.50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 % of Full Scale (ms)\u003c\/td\u003e\n\u003ctd\u003e0.75\u003c\/td\u003e\n\u003ctd\u003e1.0\u003c\/td\u003e\n\u003ctd\u003e1.2\u003c\/td\u003e\n\u003ctd\u003e5.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePositioning Speed (m\/s)\u003c\/td\u003e\n\u003ctd\u003e12.0\u003c\/td\u003e\n\u003ctd\u003e10.0\u003c\/td\u003e\n\u003ctd\u003e8.0\u003c\/td\u003e\n\u003ctd\u003e5.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScan Angle (°)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGain Error (mrad)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u0026lt; 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero Offset (mrad)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u0026lt; 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±15 VDC, ≥ 3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e16bit: XY2-100   20bit: ST2-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Temperature (°C)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e25 ± 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Water Requirements\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e5 l\/min at △p \u0026lt; 0.1 bar, p \u0026lt; 4 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e1.9\u003c\/td\u003e\n\u003ctd\u003e2.3\u003c\/td\u003e\n\u003ctd\u003e5.0\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eExtraScan IV\u003c\/th\u003e\n\u003cth\u003eExtraScan IV 10\u003c\/th\u003e\n\u003cth\u003eExtraScan IV 14\u003c\/th\u003e\n\u003cth\u003eExtraScan IV 20\u003c\/th\u003e\n\u003cth\u003eExtraScan IV 30\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Beam Aperture (mm)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBeam Displacement (mm)\u003c\/td\u003e\n\u003ctd\u003e12.67\u003c\/td\u003e\n\u003ctd\u003e16.42\u003c\/td\u003e\n\u003ctd\u003e24.73\u003c\/td\u003e\n\u003ctd\u003e35.35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTracking Error (ms)\u003c\/td\u003e\n\u003ctd\u003e0.14\u003c\/td\u003e\n\u003ctd\u003e0.16\u003c\/td\u003e\n\u003ctd\u003e0.20\u003c\/td\u003e\n\u003ctd\u003e0.45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability (µrad)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOffset Drift (µrad\/K)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 12\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 12\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 12\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGain Drift (ppm\/K)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 8\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 8\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 8\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong-term Drift Over 8 Hours (mrad)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.04\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.04\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.04\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 % of Full Travel (ms)\u003c\/td\u003e\n\u003ctd\u003e0.30\u003c\/td\u003e\n\u003ctd\u003e0.4\u003c\/td\u003e\n\u003ctd\u003e0.60\u003c\/td\u003e\n\u003ctd\u003e1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 % of Full Travel (ms)\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003ctd\u003e0.8\u003c\/td\u003e\n\u003ctd\u003e1.0\u003c\/td\u003e\n\u003ctd\u003e3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePositioning Speed (rad\/s)\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Scan Angle (°)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGain Error (mrad)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u0026lt; 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero Offset (mrad)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u0026lt; 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNonlinearity (%)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u0026lt; 0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e+30 – 48 VDC, ≥ 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eXY2-100 \/ ST2-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Temperature (°C)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e25 ± 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Water Requirements\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e5 l\/min at △p \u0026lt; 0.1 bar, p \u0026lt; 4 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e1.9\u003c\/td\u003e\n\u003ctd\u003e2.3\u003c\/td\u003e\n\u003ctd\u003e5.0\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eData Sheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0108\/0619\/8330\/files\/ExtraScan-Head-HJ-spec-sheet.pdf?v=1791418192\"\u003eExtraScan Head (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003eExtraScan I, II and IV series, 10 mm to 30 mm apertures. Tell us your laser type and application and we will quote the right scan head.\u003c\/p\u003e","brand":"HJ Optronics, Inc.","offers":[{"title":"Default Title","offer_id":67637834743882,"sku":"ExtraScan Head","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0108\/0619\/8330\/files\/extrascan-head-1.jpg?v=1791418196","url":"https:\/\/hjoptronicsinc.com\/products\/extrascan-head","provider":"HJ Optronics, Inc.","version":"1.0","type":"link"}