{"product_id":"ultrascan-head","title":"UltraScan Head","description":"\u003cp\u003e\u003cstrong\u003eUltraScan Head\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe UltraScan Head is a range of 2-axis (2D) galvanometer scan heads covering 10 \/ 14 \/ 20 \/ 30 \/ 50 mm apertures, with a rich mirror coating selection - UV, green, fiber, CO₂ and other options - and strict mirror quality control for flatness and damage threshold. The driver board uses a Class D power amplifier for high output power, low heating and low drift, and strict factory inspection keeps the repair rate very low. Two series are available: UltraScan I and the UltraScan II family.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eLow noises, high linearity and low drift\u003c\/li\u003e\n\u003cli\u003eModular design, easy installment and maintenance\u003c\/li\u003e\n\u003cli\u003eSupport varieties of F-theta lenses\u003c\/li\u003e\n\u003cli\u003eAvailable to general protocol (XY2-100) and other protocol\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications of UltraScan Head\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct\u003c\/td\u003e\n\u003ctd\u003eUltraScan Head\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003e2-axis (2D) galvanometer scan head with Class D driver board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAperture Range\u003c\/td\u003e\n\u003ctd\u003e7 mm to 50 mm (model dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMirror Coatings\u003c\/td\u003e\n\u003ctd\u003eUV, green, fiber, CO₂ options, and other coatings on request\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF-theta Lenses\u003c\/td\u003e\n\u003ctd\u003eSupports a wide range of F-theta lenses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Applications\u003c\/td\u003e\n\u003ctd\u003eLaser marking and cutting of non-metallic materials and selected metals: packaging (food, beverage, pharmaceutical), ceramics, electronic components, consumer device housings, buttons, nameplates, PCB barcodes, wire stripping and film cutting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eUltraScan I\u003c\/th\u003e\n\u003cth\u003eUltraScan10 ①\u003c\/th\u003e\n\u003cth\u003eUltraScan10 ②\u003c\/th\u003e\n\u003cth\u003eUltraScan10 ③\u003c\/th\u003e\n\u003cth\u003eUltraScan14\u003c\/th\u003e\n\u003cth\u003eUltraScan20\u003c\/th\u003e\n\u003cth\u003eUltraScan30\u003c\/th\u003e\n\u003cth\u003eUltraScan50\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Beam Aperture (mm)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBeam Displacement (mm)\u003c\/td\u003e\n\u003ctd\u003e12.54\u003c\/td\u003e\n\u003ctd\u003e12.54\u003c\/td\u003e\n\u003ctd\u003e12.54\u003c\/td\u003e\n\u003ctd\u003e16.42\u003c\/td\u003e\n\u003ctd\u003e25.25\u003c\/td\u003e\n\u003ctd\u003e35.61\u003c\/td\u003e\n\u003ctd\u003e62.25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTracking Error (ms)\u003c\/td\u003e\n\u003ctd\u003e0.14\u003c\/td\u003e\n\u003ctd\u003e0.14\u003c\/td\u003e\n\u003ctd\u003e0.14\u003c\/td\u003e\n\u003ctd\u003e0.23\u003c\/td\u003e\n\u003ctd\u003e0.45\u003c\/td\u003e\n\u003ctd\u003e0.70\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability (µrad)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 3\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOffset Drift (µrad\/K)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 15\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 15\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 15\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 15\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 15\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 15\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGain Drift (ppm\/K)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 80\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 80\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 80\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 80\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 80\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 80\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong-term Drift Over 8 Hours (mrad)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.15\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.15\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.15\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.15\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.15\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.15\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 % of Full Scale (ms)\u003c\/td\u003e\n\u003ctd\u003e0.40\u003c\/td\u003e\n\u003ctd\u003e0.30\u003c\/td\u003e\n\u003ctd\u003e0.35\u003c\/td\u003e\n\u003ctd\u003e0.65\u003c\/td\u003e\n\u003ctd\u003e0.80\u003c\/td\u003e\n\u003ctd\u003e1.20\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 % of Full Scale (ms)\u003c\/td\u003e\n\u003ctd\u003e1.20\u003c\/td\u003e\n\u003ctd\u003e1.00\u003c\/td\u003e\n\u003ctd\u003e1.10\u003c\/td\u003e\n\u003ctd\u003e1.60\u003c\/td\u003e\n\u003ctd\u003e2.50\u003c\/td\u003e\n\u003ctd\u003e4.50\u003c\/td\u003e\n\u003ctd\u003e6.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePositioning Speed (m\/s) ④\u003c\/td\u003e\n\u003ctd\u003e10.0\u003c\/td\u003e\n\u003ctd\u003e20.0\u003c\/td\u003e\n\u003ctd\u003e15.0\u003c\/td\u003e\n\u003ctd\u003e10.0\u003c\/td\u003e\n\u003ctd\u003e5.0\u003c\/td\u003e\n\u003ctd\u003e3.0\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScan Angle (°) ⑤\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e±25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGain Error (mrad)\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e\u0026lt; 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero Offset (mrad)\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e\u0026lt; 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNonlinearity (%)\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e\u0026lt; 0.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e±15 VDC, ≥ 3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol ⑥\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e16bit: XY2-100   20bit: ST2-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Temperature (°C)\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e25 ± 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e1.9\u003c\/td\u003e\n\u003ctd\u003e1.9\u003c\/td\u003e\n\u003ctd\u003e1.9\u003c\/td\u003e\n\u003ctd\u003e2.3\u003c\/td\u003e\n\u003ctd\u003e5.0\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003ctd\u003e8.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e① Customization for precision marking. ② Customization for marking on the fly. ③ Customization for FPC and SLA applications. ④ Test using F-theta lens with focal length F=160 mm. ⑤ All angles above are optical angles.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eUltraScan II\u003c\/th\u003e\n\u003cth\u003eUltraScan II 7\u003c\/th\u003e\n\u003cth\u003eUltraScan II 10\u003c\/th\u003e\n\u003cth\u003eUltraScan II 14\u003c\/th\u003e\n\u003cth\u003eUltraScan II 20\u003c\/th\u003e\n\u003cth\u003eUltraScan II 30\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Beam Aperture (mm)\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBeam Displacement (mm)\u003c\/td\u003e\n\u003ctd\u003e9.77\u003c\/td\u003e\n\u003ctd\u003e12.54\u003c\/td\u003e\n\u003ctd\u003e16.42\u003c\/td\u003e\n\u003ctd\u003e25.25\u003c\/td\u003e\n\u003ctd\u003e35.53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTracking Error (ms)\u003c\/td\u003e\n\u003ctd\u003e0.12\u003c\/td\u003e\n\u003ctd\u003e0.12\u003c\/td\u003e\n\u003ctd\u003e0.15\u003c\/td\u003e\n\u003ctd\u003e0.35\u003c\/td\u003e\n\u003ctd\u003e0.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability (µrad)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOffset Drift (µrad\/K)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 12\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 12\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 12\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 12\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGain Drift (ppm\/K)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 50\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 50\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 50\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 50\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong-term Drift Over 8 Hours (mrad)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.1\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.1\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.1\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.1\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 % of Full Scale (ms)\u003c\/td\u003e\n\u003ctd\u003e0.22\u003c\/td\u003e\n\u003ctd\u003e0.30\u003c\/td\u003e\n\u003ctd\u003e0.35\u003c\/td\u003e\n\u003ctd\u003e0.70\u003c\/td\u003e\n\u003ctd\u003e1.10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 % of Full Scale (ms)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003ctd\u003e0.80\u003c\/td\u003e\n\u003ctd\u003e0.90\u003c\/td\u003e\n\u003ctd\u003e2.40\u003c\/td\u003e\n\u003ctd\u003e4.40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePositioning Speed (m\/s) ①\u003c\/td\u003e\n\u003ctd\u003e25.0\u003c\/td\u003e\n\u003ctd\u003e18.0\u003c\/td\u003e\n\u003ctd\u003e14.0\u003c\/td\u003e\n\u003ctd\u003e6.0\u003c\/td\u003e\n\u003ctd\u003e4.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScan Angle (°) ②\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e±25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGain Error (mrad)\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e\u0026lt; 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero Offset (mrad)\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e\u0026lt; 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNonlinearity (%)\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e\u0026lt; 0.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e±15 VDC, ≥ 3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e16bit: XY2-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Temperature (°C)\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e25 ± 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e1.6\u003c\/td\u003e\n\u003ctd\u003e1.9\u003c\/td\u003e\n\u003ctd\u003e2.3\u003c\/td\u003e\n\u003ctd\u003e5.0\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e① Test using F-theta lens with focal length F=160 mm. ② All angles above are optical angles.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eData Sheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0108\/0619\/8330\/files\/UltraScan-Head-HJ-spec-sheet.pdf?v=1791417917\"\u003eUltraScan Head (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003eUltraScan I and UltraScan II series, 7 mm to 50 mm apertures. Tell us your laser type and application and we will quote the right scan head.\u003c\/p\u003e","brand":"HJ Optronics, Inc.","offers":[{"title":"Default Title","offer_id":67637795979338,"sku":"UltraScan Head","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0108\/0619\/8330\/files\/ultrascan-head-1.jpg?v=1791417921","url":"https:\/\/hjoptronicsinc.com\/products\/ultrascan-head","provider":"HJ Optronics, Inc.","version":"1.0","type":"link"}