{"product_id":"ultrascan-ii-gs-galvo-head","title":"UltraScan II GS Galvo Head","description":"\u003cp\u003e\u003cstrong\u003eUltraScan II GS Galvo Head\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe UltraScan II GS Galvo Head is designed for high-speed, high-precision laser processing. It delivers a maximum scan speed exceeding 240 rad\/s and supports fiber laser power up to 3 kW, with a newly engineered water-cooling structure that keeps the motor and drive thermally stable during continuous operation. High positioning accuracy keeps long-term drift below 100 µrad for stable, repeatable laser scanning. Five aperture sizes are available: 10, 14, 15, 20 and 30 mm.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMaximum scan speed is greater than 240rad\/s.\u003c\/li\u003e\n\u003cli\u003eNew water-cooling design to cool motor and drive efficiently.\u003c\/li\u003e\n\u003cli\u003eMaximum 3KW fiber laser power.\u003c\/li\u003e\n\u003cli\u003eHigh precision. Long term drift is less than 100µrad.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications of UltraScan II GS Galvo Head\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct\u003c\/td\u003e\n\u003ctd\u003eUltraScan II GS Galvo Head\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003e2-axis galvanometer scan head with water-cooled motor and drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAperture Range\u003c\/td\u003e\n\u003ctd\u003e10 \/ 14 \/ 15 \/ 20 \/ 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Scan Speed\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 240 rad\/s (±24 V supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Fiber Laser Power\u003c\/td\u003e\n\u003ctd\u003e3 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong-term Drift\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 100 µrad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eWater cooled (5 l\/min at △p \u0026lt; 0.1 bar, p \u0026lt; 4 bar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Applications\u003c\/td\u003e\n\u003ctd\u003eHigh-speed fiber laser marking, cutting and welding where thermal stability matters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eUltraScan II-GS\u003c\/th\u003e\n\u003cth\u003e10mm\u003c\/th\u003e\n\u003cth\u003e14mm\u003c\/th\u003e\n\u003cth\u003e15mm\u003c\/th\u003e\n\u003cth\u003e20mm\u003c\/th\u003e\n\u003cth\u003e30mm\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Beam Aperture (mm)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBeam Displacement (mm)\u003c\/td\u003e\n\u003ctd\u003e12.54\u003c\/td\u003e\n\u003ctd\u003e16.42\u003c\/td\u003e\n\u003ctd\u003e19.32\u003c\/td\u003e\n\u003ctd\u003e25.25\u003c\/td\u003e\n\u003ctd\u003e35.53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTracking Error (ms)\u003c\/td\u003e\n\u003ctd\u003e0.12\u003c\/td\u003e\n\u003ctd\u003e0.19\u003c\/td\u003e\n\u003ctd\u003e0.20\u003c\/td\u003e\n\u003ctd\u003e0.30\u003c\/td\u003e\n\u003ctd\u003e0.55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability (µrad)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOffset Drift (µrad\/K)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 12\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 12\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 12\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 12\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGain Drift (ppm\/K)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 50\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 50\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 50\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 50\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong-term Drift Over 8 Hours (mrad)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.1\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.1\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.1\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.1\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 % of Full Scale (ms)\u003c\/td\u003e\n\u003ctd\u003e0.28\u003c\/td\u003e\n\u003ctd\u003e0.38\u003c\/td\u003e\n\u003ctd\u003e0.45\u003c\/td\u003e\n\u003ctd\u003e0.70\u003c\/td\u003e\n\u003ctd\u003e1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 % of Full Scale (ms)\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003ctd\u003e0.72\u003c\/td\u003e\n\u003ctd\u003e0.8\u003c\/td\u003e\n\u003ctd\u003e1.1\u003c\/td\u003e\n\u003ctd\u003e3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePositioning Speed (rad\/s)\u003c\/td\u003e\n\u003ctd\u003e200 @ ±15 V \/ 240 @ ±24 V\u003c\/td\u003e\n\u003ctd\u003e200 @ ±15 V \/ 240 @ ±24 V\u003c\/td\u003e\n\u003ctd\u003e200 @ ±15 V \/ 220 @ ±24 V\u003c\/td\u003e\n\u003ctd\u003e130 @ ±15 V \/ 180 @ ±24 V\u003c\/td\u003e\n\u003ctd\u003e70 @ ±15 V \/ 100 @ ±24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Scan Angle (°)\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e±22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGain Error (mrad)\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e\u0026lt; 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero Offset (mrad)\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e\u0026lt; 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNonlinearity (%)\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e\u0026lt; 0.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e±15 VDC – ±24 VDC, ≥ 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e16bit: XY2-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Temperature (°C)\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e25 ± 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Water Requirements\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e5 l\/min at △p \u0026lt; 0.1 bar, p \u0026lt; 4 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e1.9\u003c\/td\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003ctd\u003e5.0\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eData Sheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0108\/0619\/8330\/files\/UltraScan-II-GS-Galvo-Head-HJ-spec-sheet.pdf?v=1791427999\"\u003eUltraScan II GS Galvo Head (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003eFive aperture sizes, 10 mm to 30 mm, water cooled for continuous operation. Tell us your laser type and application and we will quote the right scan head.\u003c\/p\u003e","brand":"HJ Optronics, Inc.","offers":[{"title":"Default Title","offer_id":67638351102026,"sku":"UltraScan II GS Galvo Head","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0108\/0619\/8330\/files\/ultrascan-ii-gs-1.jpg?v=1791428003","url":"https:\/\/hjoptronicsinc.com\/products\/ultrascan-ii-gs-galvo-head","provider":"HJ Optronics, Inc.","version":"1.0","type":"link"}