LC-15K 15 kW High Power Laser Cable
Description
HJ's 15 kW Laser Cable provides QBH compatible connector for high power fiber lasers up to 15 kW. Technologies incorporated include cladding mode stripping, indirect water cooling and safety interlock.
Key Features
- Low Insertion Loss
- High Power Handling
- High Backward Power Handling
- Indirect Water Cooling
- Safety Interlock
Applications
- Fiber Lasers
- Fiber Coupling
Specifications
| Parameter | Unit | Value |
|---|---|---|
| Operation Wavelength | nm | 945 ± 50 or 1080 ± 30 |
| Numerical Aperture (NA) | - | ≤ 0.22 |
| Max. Transmission Loss of Fiber Core | % | 2 |
| Max. Power Handling | kW | 8 - 15 |
| Max. Peak Power | - | Max. 50 kW @ 1 ms |
| Max. Stripping Cladding Power | - | 1 kW for 10 min |
| Max. Z-Position Tolerance | μm | ± 50 |
| Max. Angular Deviation | mrad | 10 |
| Cooling Water Requirements | ||
| Flow Rate | L/min | 1.5 - 3.0 |
| Max. Water Pressure | MPa | 0.8 |
| Water Temperature | °C | 10 - 45 |
| Water Hose Diameter | mm | ID/OD = 4/6 |
| Others | ||
| Mechanical Interface | - | Compatible with the Standard QBH Interface |
| Type of Cable Gland | - | Metal |
| Min. Fiber Tensile Load | N | 5 |
| Operating Temperature | °C | + 5 to + 50 |
| Storage Temperature | °C | - 20 to + 70 |
| Safety Interlock | ||
| Interlock Circuit Resistance | 3.3 kΩ ± 5% + 2 Ω/m fiber | |
| Thermo-Switch Limit | 70 ° C ± 5 ° C, Reset temp. < 30 ° C | |
| Max. Working Voltage | - | 33 V |
Download the data sheet.